What are the common problems with online guillotine PCB splitters?
In daily production, although the guillotine PCB splitter is easy to use, there will always be problems of one kind or another. Zhimao PCB splitter has sorted out five small points for your reference.
1. If the indicator light does not light up after the power switch of the guillotine PCB splitter is turned on:
One possibility is that the fuse is fused and needs to be replaced; another possibility is that the emergency switch is not turned on.
2. The stroke of the guillotine PCB splitter is inaccurate:
One possibility is that the stroke counter is broken and needs to be replaced; another possibility is that the stroke counter is too dusty, just clean the dust.
3. The knife of the guillotine PCB splitter hits the left board:
One possibility is that the left stroke photosensitive switch is broken and needs to be replaced; another possibility is that the left stroke switch is too dusty, just clean the dust.
4. The knife of the guillotine PCB splitter hits the right side board:
One possibility is that the right stroke photosensitive switch is broken and needs to be replaced; another possibility is that there is too much dust on the right stroke switch, just clean the dust.
5. The motor of the guillotine PCB splitter rotates, but the knife does not rotate:
The coupling top screw is loose, open the back cover, and tighten the top screw.
The above are five daily problems of online guillotine PCB splitters and their solutions.
If you have different suggestions or questions, you can also contact Zhimao automatic PCB splitter.
Zhimao automatic pcba splitter has technical service bases across the country, and can provide door-to-door service at any time to solve any problems in the daily production of PCB splitters.